Indoor Gas-Insulated Load Switch for Medium Voltage Applications

Product Details
Customization: Available
Type: High-voltage
Structure: Three-column Disconnector
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 7 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (26)
  • Indoor Gas-Insulated Load Switch for Medium Voltage Applications
  • Indoor Gas-Insulated Load Switch for Medium Voltage Applications
  • Indoor Gas-Insulated Load Switch for Medium Voltage Applications
  • Indoor Gas-Insulated Load Switch for Medium Voltage Applications
  • Indoor Gas-Insulated Load Switch for Medium Voltage Applications
Find Similar Products

Basic Info.

Model NO.
VNA
Operation
Manual
Grounding Mode
Grounding
Movement Mode
Horizontal Rotary Type
Number of Poles
Three Pole
Grounding
Single Ground
Series
Three
Run
Turn the Horizontal
Switching Mode
Single Throw-in
Common Model
Vna
Structure of Operating
Manual
Certification
IS9001
Brand
Custom-Made
Rated Voltage
10kv
Rated Current
400,630A
Rated Short-Circuit Current, a
400,630A
Rated Operating Voltage
20ka
Transport Package
Carton Packing
Specification
1200*480*650mm
Trademark
ZGHQDL
Origin
China
HS Code
8535309090
Production Capacity
10000/M

Product Description

 Indoor Gas-Insulated Load Switch for Medium Voltage Applications      
The gas-insulated load switches of type VNA-10 are designed for switching on and off under load sections of electrical circuits with three-phase alternating current rated at 400 A and 630 A, with a frequency of 50-60 Hz, and a nominal voltage of up to 10 kV. They also provide safe operation for maintenance work on the de-energized section using stationary grounding devices.

The PRBD-10 drive is intended for manual operation of the switch. In the off position, the VNA-10 creates a visible break in the electrical circuit, similar to a regular isolator. When disconnected, an arc forms between the arc-extinguishing contacts. Due to the high temperature of the arc, polymethyl methacrylate releases a large amount of gases, which extinguish the arc.

When closing, the arc-extinguishing contacts are closed first, followed by the main contacts. When opening, the main contacts are opened first, followed by the arc-extinguishing contacts.

The VNA includes a locking mechanism that prevents the grounding blades from being closed when the switch is in the on position and vice versa. The blades are operated by a separate mechanical drive (PRBD) connected to the load switch via a mechanical transmission. The switch drive can be placed either on the right (P) or on the left (L) relative to the main shaft of the switch.

Load switches with a rated current of 400 A are made with polymer insulators IOLp-10; those rated at 630 A use porcelain insulators IOR-10-3.75. At the customer's request, a device with a rated current of 630 A can also be manufactured with polymer insulators.
Indoor Gas-Insulated Load Switch for Medium Voltage Applications
Indoor Gas-Insulated Load Switch for Medium Voltage ApplicationsIndoor Gas-Insulated Load Switch for Medium Voltage ApplicationsIndoor Gas-Insulated Load Switch for Medium Voltage Applications
Name of parameters
Parameter value
Rated voltage Unom, kV
10
Rated operating voltage Unr, kV
12
Rated current, A
400, 630
The nominal initial value of the periodic component of the through short-circuit current Inp,
kA
20
Rated tripping current, A
400, 630
Normative parameters of the through short-circuit current:
maximum peak current (electrodynamic withstand current), kA;
initial RMS value of the periodic component, kA;
root mean square value of the current over its duration (thermal withstand current), kA;
short-circuit current duration tkz , s.
51
20
20
1
Normalized parameters of inrush current:
maximum peak, kA,
initial RMS value of the periodic component, kA.
51
20
Switching capacity in normal operating conditions, VO.
10 cycles
The electrical resistance of the main current-carrying circuits in the closed position of the
circuit breaker must not exceed, µΩ
100
The insulation resistance of movable and guiding parts made of organic materials must not be
less than the specified values, MΩ
1000
Mechanical wear resistance, cycles (on-off-random pause) not less than.
2000
Power consumed by the device per pole.
400 А - 12,3 W
630 А - 21,8 W


Indoor Gas-Insulated Load Switch for Medium Voltage ApplicationsIndoor Gas-Insulated Load Switch for Medium Voltage ApplicationsIndoor Gas-Insulated Load Switch for Medium Voltage Applications
Indoor Gas-Insulated Load Switch for Medium Voltage ApplicationsIndoor Gas-Insulated Load Switch for Medium Voltage ApplicationsIndoor Gas-Insulated Load Switch for Medium Voltage ApplicationsIndoor Gas-Insulated Load Switch for Medium Voltage Applications





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier